TYPDETAIL

Home / Walls & Shear Walls

Continuous Tiedown System - Three Story Elevation - typical walls & shear walls detail drawing, DWG
Preview of continuous tiedown system - three story elevation. The DWG is fully editable.

Text on the drawing

5/8" DIA. ROD - 3RD STORY (1) 2X STUD EA. SIDE ROD COUPLER, TYP. 2X COMPRESSION BLOCKS IN FLOOR DEPTH EA. SIDE OF ROD 7/8" DIA. ROD - 2ND STORY (2) 2X STUDS EA. SIDE FLOOR FRAMING & SHEATHING 1" DIA. ROD - 1ST STORY (3) 2X STUDS EA. SIDE (2) 2X TOP PLATE P.T. SILL PLATE CAST-IN ANCHOR W/ PLATE WASHER IN FOUNDATION ROD AND STUD SIZES SHOWN ARE TYPICAL FOR 3-STORY WOOD FRAME; FINAL SIZES BY TIEDOWN MFR. PER UPLIFT. INSTALL TAKE-UP DEVICES AT EVERY LEVEL. LIMIT ROD ELONGATION + DEVICE DEFLECTION TO 0.20" PER STORY. BEARING PLATE & SHRINKAGE TAKE-UP DEVICE AT EA. LEVEL N.T.S.