Codes and approvals referenced
Text on the drawing
2X6 STUD WALL W/ R-5 CONT. EXTERIOR INSULATION 2X10 JOISTS @ 16" O.C. P.T. 2X6 SILL ON GASKET, 5/8" A.B. @ 6'-0" O.C. 2" RIGID INSULATION (R-10) FULL HEIGHT OF WALL & OVER RIM PROTECTIVE COATING ON FOAM, TOP OF WALL TO 6" BELOW GRADE GRADE 8" MIN. BELOW SILL, SLOPE 6" IN 10'-0" AWAY 8" CONC. STEM WALL, #4 CONT. TOP & BOT. 10 MIL VAPOR RETARDER OVER CRAWL FLOOR, LAPPED 12" UP WALL & SEALED 18"X8" FOOTING W/ (3) #4 UNVENTED (CONDITIONED) CRAWL SPACE PER CRC R408.3: SEALED VAPOR RETARDER AND MECHANICAL CONDITIONING. 18" MIN. CLEARANCE GRADE TO JOISTS. TERMITE INSPECTION GAP OR SHIELD AT TOP OF FOAM WHERE REQUIRED. N.T.S.