TYPDETAIL

Home / Repairs & Existing

Cripple Wall Seismic Retrofit - Section - typical repairs & existing detail drawing, DWG
Preview of cripple wall seismic retrofit - section. The DWG is fully editable.

Codes and approvals referenced

A35LTP4TITEN HD

Text on the drawing

(E) FLOOR JOISTS / RIM A35 / LTP4 @ 16" O.C. RIM TO TOP PLATE (FEMA P-1100) 15/32" WSP ON INSIDE OR OUTSIDE FACE, 8d @ 4" EDGES / 12" FIELD RETROFIT SILL ANCHOR (UFP10 / TITEN HD) @ 32" O.C. PER PLAN (E) FOUNDATION PRESCRIPTIVE RETROFIT PER CEBC APPENDIX A3 / FEMA P-1100 OR ENGINEERED DESIGN. VENT HOLES IN WSP (1-1/2" DIA.) FOR CRAWL SPACE. VERIFY (E) FOUNDATION CONDITION BEFORE INSTALLING ANCHORS. N.T.S.