Preview of decayed mudsill replacement at raised floor detail. The DWG is fully editable.

Codes and approvals referenced

ESR-2713TITEN HD

Text on the drawing

(E) FLOOR JOISTS / RIM STEEL SHIMS DRIVEN TIGHT UNDER RIM, FULL BEARING NEW 2X6 P.T. SILL, CUT OUT DECAYED SECTION TO SOUND WOOD + 12" 1/2" TITEN HD (ESR-2713) @ 32" O.C., 2 MIN. PER PIECE, W/ 3"X3"X0.229" PLATE WASHER (E) STEM WALL SHORE FLOOR WITHIN 24" OF WORK BEFORE CUTTING SILL. REPLACE IN 8'-0" MAX. LENGTHS. TREAT CUT ENDS OF P.T. LUMBER (AWPA M4). IDENTIFY AND CORRECT MOISTURE SOURCE. N.T.S.