TYPDETAIL

Home / Repairs & Existing

Decayed Post Base Replacement - Elevation - typical repairs & existing detail drawing, DWG
Preview of decayed post base replacement - elevation. The DWG is fully editable.

Codes and approvals referenced

CRC R304.1.4).ESR-1622ESR-2713TITEN HD

Text on the drawing

(E) POST ABOVE, SOUND WOOD CUT POST ABOVE DECAY, NEW P.T. POST SECTION; SHORE BEAM DURING WORK NEW ABU POST BASE (ESR-1622) W/ FASTENERS PER MFR. SPLICE AT CUT W/ (2) STEEL SIDE PLATES OR SCABS PER ENGINEER WHERE POST IS NOT LATERALLY BRACED. MAINTAIN 1" MIN. STANDOFF ABOVE CONC. (CRC R304.1.4). TREAT CUT ENDS W/ PRESERVATIVE. 5/8" TITEN HD (ESR-2713) OR EPOXY ANCHOR, EMBED PER MFR. (E) FOOTING / PIER 1" = 1'-0"