Deck Beam on Notched 6x6 Post - (2) 2x12 Beam Detail - typical floor framing & decks detail drawing, DWG
Preview of deck beam on notched 6x6 post - (2) 2x12 beam detail. The DWG is fully editable.

Codes and approvals referenced

AWC DCA 6H2.5A

Text on the drawing

2X JOIST PER PLAN (2) 2X12 P.T. BEAM, FULL BEARING ON NOTCH, PLIES NAILED W/ (2) ROWS 10d @ 12" O.C. (2) 1/2" DIA. GALV. THRU-BOLTS W/ WASHERS 6X6 P.T. POST, NOTCH TO 2 1/2" REMAINING MIN. PER AWC DCA 6. POST ON FOOTING W/ SIMPSON ABU66Z. BEAM SPLICES OCCUR OVER POSTS ONLY. ALL HARDWARE HOT-DIP GALV. OR STAINLESS FOR P.T. LUMBER CONTACT. SIMPSON H2.5A OR LUS HANGER EA. JOIST TO BEAM N.T.S.