TYPDETAIL

Home / Floor Framing & Decks

Deck Joist and Beam Cantilever Limits - Elevation - typical floor framing & decks detail drawing, DWG
Preview of deck joist and beam cantilever limits - elevation. The DWG is fully editable.

Codes and approvals referenced

CRC TABLE R507.6

Text on the drawing

BACKSPAN L L/4 MAX. BEAM SPAN JOIST CANTILEVER L/4 MAX. AND PER CRC TABLE R507.6 (BY JOIST SIZE) DROPPED BEAM PER PLAN POST PER PLAN BEAM CANTILEVER PAST POST L/4 OF ADJ. SPAN MAX. (R507.5) CANTILEVERS SUPPORT UNIFORM DECK LOAD ONLY; NO HOT TUBS, PLANTERS OR POSTS AT CANTILEVER ENDS WITHOUT ENGINEERING. GUARD POSTS AT CANTILEVER PER GUARD DETAIL. 1/4" = 1'-0"