Codes and approvals referenced
Text on the drawing
DECKING PER PLAN FLASHING LAPPED UNDER BUILDING PAPER / WRB 2X8 DECK JOIST PER PLAN W/ SIMPSON LUS28 HANGER 2X8 P.T. LEDGER W/ 1/2" DIA. THRU-BOLTS @ 24" O.C. STAGGERED (2" EDGE DIST.) RIM BOARD (1 1/8" MIN.) EXTERIOR WALL PER PLAN FLOOR JOIST PER PLAN N.T.S.