Text on the drawing
8'-0" PANEL BOUNDARY NAILING (B.N.) AT PERIMETER, COLLECTORS & SHEAR WALL LINES RIM / BLOCKING / TOP PLATE AT BOUNDARY EDGE NAILING (E.N.) AT SUPPORTED PANEL EDGES PANEL STRENGTH AXIS PERPENDICULAR TO JOISTS FIELD NAILING (F.N.) AT INTERMEDIATE SUPPORTS STAGGER END JOINTS 4'-0", BEAR ON JOIST, 1/8" GAP JOISTS / TRUSSES @ 16" O.C. (24" O.C. MAX.) USE SHEATHING (APA RATED) B.N. E.N. F.N. NAIL ROOF 15/32" WSP, 32/16 6" O.C. 6" O.C. 12" O.C. 8d COMMON (0.131"X2 1/2") FLOOR 23/32" T&G, 48/24 6" O.C. 6" O.C. 12" O.C. 10d COMMON, GLUED HIGH LOAD 15/32" WSP, BLOCKED 4" O.C. 6" O.C. 12" O.C. 8d COMMON, 3X FRAMING UNBLOCKED DIAPHRAGM U.N.O. (SDPWS TABLE 4.2C, CASE 1). MIN. PANEL 24" WIDE; PANEL CLIPS AT 24" SPANS. NAILS 3/8" MIN. FROM PANEL EDGES; DO NOT OVERDRIVE. PROTECT SHEATHING FROM WEATHER BEFORE ROOFING. N.T.S.