Codes and approvals referenced
Text on the drawing
COLLECTOR LENGTH 2X SOLID BLOCKING, TIGHT FIT, A35 CLIP EA. BLOCK TO PLATE (2) 2X TOP PLATE, SPLICES OFFSET 48" SHEAR WALL PER PLAN & SCHEDULE, E.N. TO BOTH TOP PLATES COLLECTOR TRANSFERS DIAPHRAGM SHEAR TO THE SHEAR WALL (ASCE 7 12.10.2). DIAPHRAGM B.N. 10d @ 4" O.C. ALONG COLLECTOR AND WALL. ALT.: STRAP ON FACE OF TOP PLATES. STRAP LENGTH AND NAILING PER PLAN. SIMPSON CMST14 COIL STRAP ON TOP PLATES, FULL LENGTH OF COLLECTOR & 48" MIN. ONTO SHEAR WALL, 16d @ 3" O.C. STAGGERED N.T.S.