TYPDETAIL

Home / Walls & Shear Walls

Embedded Strap Holdown - STHD14 Detail - typical walls & shear walls detail drawing, DWG
Preview of embedded strap holdown - sthd14 detail. The DWG is fully editable.

Codes and approvals referenced

STHD14

Text on the drawing

(2) 2X STUDS MIN. (OR PER PLAN) SIMPSON STHD14 STRAP W/ (30) 16d SINKERS TO POST STRAP EMBEDDED IN CONC., SET BEFORE POUR, 1 1/2" MIN. FROM SLAB EDGE P.T. 2X SILL PLATE CONCRETE SLAB PER PLAN INSTALL PER MANUFACTURER. HOLDOWN LOCATIONS PER SHEAR WALL PLAN. USE HDG / ZMAX FINISH AND MATCHING FASTENERS AT P.T. LUMBER. (1) #4 TOP & BOTTOM CONT. N.T.S.

More walls & shear walls details

Shear Wall Hold-Down Detail - DWG drawing

Shear Wall Hold-Down Detail

Top Plate Splice Detail - DWG drawing

Top Plate Splice Detail

Typical Joist and Stud Cutout Detail - DWG drawing

Typical Joist and Stud Cutout Detail

Typical Non-Bearing Wall to Rafter Detail - DWG drawing

Typical Non-Bearing Wall to Rafter Detail

Braced Wall Panel Intersections Detail - DWG drawing

Braced Wall Panel Intersections Detail

Interior Shear Wall Detail - DWG drawing

Interior Shear Wall Detail

Hold-Down at Raised Floor Detail - DWG drawing

Hold-Down at Raised Floor Detail

Wall-Ceiling Connection Detail - DWG drawing

Wall-Ceiling Connection Detail