Codes and approvals referenced
Text on the drawing
8" MIN. 18" MIN. 2X6 STUD WALL W/ 15/32" WSP PER SHEAR WALL SCHEDULE SOLE PLATE: 16d @ 6" O.C. E.N. 8d @ 6" O.C. TO RIM & SILL PLATE 2X10 FLOOR JOISTS @ 16" O.C. (3) 8d TOENAILS TO SILL P.T. 2X6 SILL W/ 5/8" DIA. A.B. @ 48" O.C., 7" EMBED, 3"X3" X0.229" PLATE WASHERS FINISH GRADE, SLOPE 5% AWAY FOR 10'-0" MIN. #4 VERT. @ 48" O.C. W/ STD. HOOK, (1) #4 TOP CONT. 4" PERF. FOOTING DRAIN IN GRAVEL (WHERE REQUIRED) (3) #4 CONT., 3" CLR. 6 MIL VAPOR RETARDER OVER CRAWLSPACE SOIL, LAP 6" 6" CONC. STEM WALL & FOOTING, 2500 PSI PER CRC R403.1 / R408. FOOTING 12" MIN. BELOW UNDISTURBED GRADE. PROVIDE CRAWLSPACE VENTS (1 SF PER 150 SF) AND 18"X24" ACCESS. 1500 PSF SOIL. VERIFY FOR 2- AND 3-STORY LOADS PER TABLE R403.1(1). N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail