Codes and approvals referenced
Text on the drawing
2X10 FLOOR JOIST @ 16" O.C. (OR PER PLAN) 4X10 BEAM PER PLAN 4X4 POST PER PLAN 23/32" T&G WSP SUBFLOOR SIMPSON ST292 STRAP ACROSS BUTT JOINT W/ (12) 16d 1 1/2" MIN. BEARING EA. JOIST, TOENAIL W/ (3) 8d EA. JOISTS BEAR 1 1/2" MIN. ON WOOD (CRC R502.6). PROVIDE 2X SOLID BLOCKING OVER BEAM WHERE JOISTS ARE NOT LAPPED OR WHERE BEAM LINE IS A SHEAR / COLLECTOR LINE. N.T.S.