Codes and approvals referenced
Text on the drawing
FLOOR SHEATHING, BOUNDARY NAILING TO RIM PER SCHEDULE FLOOR JOISTS / RIM PER PLAN A35 / LTP4 RIM TO TOP PLATE @ SPACING PER PLAN (IAPMO ER-112) (2) 2X TOP PLATE SHEAR WALL BELOW PER SCHEDULE DRAG / SHEAR TRANSFER PER PLAN. WHERE JOISTS ARE PARALLEL TO WALL, PROVIDE BLOCKING @ 24" O.C. 3 BAYS MIN. W/ A35 EA. BLOCK. RIM NAILED TO TOP PLATE 16d @ 6" O.C. MIN. N.T.S.