Text on the drawing
(2) 2X STUDS (MIN.) AT END OF SHEAR WALL ABOVE SIMPSON MSTC52 STRAP OVER SHEATHING W/ (24) 16d SINKERS EA. END, CENTER ON RIM JOIST 15/32" WOOD STRUCTURAL PANEL (OR PER S.W. SCHED.) MAX. 18" CLEAR SPAN AT RIM (STRAP UNNAILED ZONE) (2) 2X STUDS (MIN.) AT END OF SHEAR WALL BELOW RIM / BLOCKING FLOOR JOIST PER PLAN N.T.S.