TYPDETAIL

Home / Walls & Shear Walls

Floor to Floor Strap Holdown - MSTC52 Detail - typical walls & shear walls detail drawing, DWG
Preview of floor to floor strap holdown - mstc52 detail. The DWG is fully editable.

Text on the drawing

(2) 2X STUDS (MIN.) AT END OF SHEAR WALL ABOVE SIMPSON MSTC52 STRAP OVER SHEATHING W/ (24) 16d SINKERS EA. END, CENTER ON RIM JOIST 15/32" WOOD STRUCTURAL PANEL (OR PER S.W. SCHED.) MAX. 18" CLEAR SPAN AT RIM (STRAP UNNAILED ZONE) (2) 2X STUDS (MIN.) AT END OF SHEAR WALL BELOW RIM / BLOCKING FLOOR JOIST PER PLAN N.T.S.

More walls & shear walls details

Shear Wall Hold-Down Detail - DWG drawing

Shear Wall Hold-Down Detail

Top Plate Splice Detail - DWG drawing

Top Plate Splice Detail

Typical Joist and Stud Cutout Detail - DWG drawing

Typical Joist and Stud Cutout Detail

Typical Non-Bearing Wall to Rafter Detail - DWG drawing

Typical Non-Bearing Wall to Rafter Detail

Braced Wall Panel Intersections Detail - DWG drawing

Braced Wall Panel Intersections Detail

Interior Shear Wall Detail - DWG drawing

Interior Shear Wall Detail

Hold-Down at Raised Floor Detail - DWG drawing

Hold-Down at Raised Floor Detail

Wall-Ceiling Connection Detail - DWG drawing

Wall-Ceiling Connection Detail