Text on the drawing
2X6 STUD WALL SILL PLATE 16d @ 6" O.C. 1 1/2" GYPSUM TOPPING OVER 23/32" T&G WSP SUBFLOOR 18" OPEN-WEB FLOOR TRUSSES @ 24" O.C., BOT. CHORD BEARING 6X SOLID BLOCKING BETWEEN TRUSSES AT LEDGER BOLTS BRICK VENEER W/ 1" AIR SPACE, TIES @ 16" O.C. EA. WAY L5X5X3/8 CONT. GALV. STEEL LEDGER W/ 5/8" DIA. THRU-BOLTS @ 24" O.C.; FLASHING & WEEPS OVER 3/8" SOFT JOINT UNDER ANGLE LEDGER SIZED FOR ONE STORY (10'-0") OF 4" BRICK ABOVE. LOCATE BOLTS ABOVE MID-HEIGHT OF BLOCKING. BLOCKING, TRUSS ENDS AND STUDS BELOW CARRY THE VENEER WEIGHT; TALLER VENEER PER PLAN. N.T.S.