TYPDETAIL

Home / Repairs & Existing

Foundation Crack Epoxy Injection - Elevation - typical repairs & existing detail drawing, DWG
Preview of foundation crack epoxy injection - elevation. The DWG is fully editable.

Codes and approvals referenced

ASTM C881

Text on the drawing

INJECTION PORTS @ 8" O.C. MAX. ALONG CRACK (NOT > WALL THK.) EPOXY SURFACE SEAL BOTH FACES WHERE ACCESSIBLE STRUCTURAL EPOXY RESIN, ASTM C881 TYPE IV, LOW VISCOSITY (E) STEM WALL / FOOTING FOR NON-MOVING CRACKS 1/64" TO 1/4" WIDE. INJECT FROM LOWEST PORT UP. WIDER OR ACTIVE CRACKS, OFFSET OR SETTLEMENT: NOTIFY ENGINEER. GRIND SEAL FLUSH AFTER CURE. N.T.S.