Codes and approvals referenced
Text on the drawing
OPENING 4'-0" MAX. 4'-0" MAX. DOUBLE TRIMMER JOIST EA. SIDE, 16d @ 12" O.C. STAGGERED DOUBLE HEADER (SAME DEPTH AS JOISTS) EA. END OF OPENING SIMPSON LUS210 FACE-MOUNT HANGER AT EA. TAIL JOIST SIMPSON HUS210-2 HANGER, HEADER TO TRIMMER (4 PLACES) 2X10 JOISTS @ 16" O.C. JOISTS CUT TRIMMERS EA. SIDE HEADER EA. END HEADER HANGER (1) JOIST (NO ADD'L) (1) 2X LUS (2) JOISTS (2) 2X HUS-2 / HHUS (2) JOISTS (2) 2X HHUS / HGUS FOR 2X10 / 2X12 JOISTS AT 40 PSF LIVE LOAD, SPANS TO 16'-0". LARGER OPENINGS OR 4+ JOISTS CUT: PER PLAN. EDGE NAIL SHEATHING TO HEADERS AND TRIMMERS ALL AROUND OPENING. INSTALL HANGERS W/ ALL MFR. NAILS. N.T.S.