Text on the drawing
3'-0" MAX. GALV. / PVC-COATED WELDED WIRE GABION BASKETS, 3" x 3" MESH, LACED / SPIRAL-BOUND PER MFR. 4"-8" ANGULAR STONE FILL, HAND- PLACED, INTERNAL TIES @ 12" O.C. NON-WOVEN FILTER FABRIC BEHIND BASKETS 6" COMPACTED AGG. BASE PAD UPPER BASKET SET BACK 6" MIN. LEVEL BACKSLOPE, NO SURCHARGE. BASKET WIDTH 0.6H MIN. TALLER WALLS OR SURCHARGE PER ENGINEERED DESIGN. CONNECT ADJACENT BASKETS ALONG ALL CONTACT EDGES. INSTALL PER MFR. (ASTM A974 / A975). 3/4" = 1'-0"