Grab Bar Reinforcement at Bathroom - Elevation - typical walls & shear walls detail drawing, DWG
Preview of grab bar reinforcement at bathroom - elevation. The DWG is fully editable.

Codes and approvals referenced

CRC R328).CRC R328.1.1CRC R328.1.1)

Text on the drawing

2X8 SOLID BLOCKING FLUSH W/ FACE OF STUDS, (2) 16d EA. END BLOCKING BETWEEN 32" AND 39-1/4" ABOVE FIN. FLOOR (CRC R328.1.1) 2X STUDS @ 16" O.C. FINISH FLOOR PROVIDE AT TOILET (BACK AND SIDE WALLS), TUB AND SHOWER WALLS IN AT LEAST ONE BATHROOM ON THE ENTRY LEVEL (CRC R328). LOCATE PER CRC R328.1.1; SHOW ON INTERIOR ELEVATIONS. N.T.S.