Codes and approvals referenced
Text on the drawing
42" MIN. > 30" GUARD, 42" MIN. ABOVE WALKING SURFACE, 4" SPHERE RULE (CBC 1015 / CRC R321) STEEL POST GROUTED IN CORE-DRILLED HOLE, 6" MIN. EMBED, NON-SHRINK GROUT RETAINING WALL PER PLAN WALKING SURFACE / PATIO GUARD REQUIRED WHERE WALKING SURFACE IS > 30" ABOVE GRADE BELOW WITHIN 36" HORIZONTALLY. POST AND WALL TOP DESIGNED FOR 200 LB. AT GUARD TOP (CBC 1607.9). EDGE DISTANCE / EMBED PER PLAN. 1/2" = 1'-0"