Codes and approvals referenced
Text on the drawing
MARK MEMBER GRADE MAX. OPENING TRIMMERS EA. END KING STUDS EA. END USE 4X6 DF-L NO. 2 (1) 2X (1) 2X BRG. WALL, ROOF + CLG. 4X8 DF-L NO. 2 (1) 2X (1) 2X BRG. WALL, ROOF + CLG. 4X10 DF-L NO. 2 (2) 2X (2) 2X BRG. WALL, ROOF + CLG. 4X12 DF-L NO. 2 (2) 2X (2) 2X BRG. WALL, ROOF + CLG. (1) 2X4 FLAT DF-L NO. 2 (1) 2X NON-BRG. WALL 4X BEAM DF-L NO. 1 SPAN ON PLAN 4X POST SIZE ON PLAN 6X BEAM DF-L NO. 1 SPAN ON PLAN 6X POST SIZE ON PLAN 3 1/2" LVL 2.0E, Fb = 2600 PSI SPAN ON PLAN 4X POST DEPTH ON PLAN 5 1/4" LVL / PSL 2.0E, Fb = 2900 PSI SPAN ON PLAN 6X POST DEPTH ON PLAN 5 1/8" GLB 24F-V4 DF/DF SPAN ON PLAN 6X POST DEPTH ON PLAN HEADER / BEAM NOTES 1. H1-H4 OPENINGS: EXTERIOR BEARING WALL SUPPORTING ROOF AND CEILING ONLY, BUILDING WIDTH TO 24', ROOF LL 20 PSF (CRC TABLE R602.7(1), EQUIVALENT (2) 2X). 2. HEADERS SUPPORTING FLOORS, GIRDER TRUSSES OR CONCENTRATED LOADS: USE BEAM MARK (B1-B5) W/ SIZE SHOWN ON PLAN. 3. FULL BEARING ON TRIMMERS; KING STUDS FULL HEIGHT, NAILED TO HEADER W/ (4) 16d EA. END. H5 PER CRC R602.7.4 (24" MAX. TO PLATE ABOVE). 4. ENGINEERED LUMBER PER MFR. EVALUATION REPORT; DO NOT NOTCH OR BORE. DELETE ROWS NOT USED ON PROJECT. N.T.S.
More general details

Braced Wall Lines and Panels - CRC R602.10 Detail

Wall Sheathing / Shear Wall Schedule

Common Wire Nail Sizes and Nail Loading Detail

Fireblocking and Draftstopping Detail

Mean Roof Height and Stories Above Grade Detail

Vertical Floor Offset - Shear Transfer Detail

Diaphragm Aspect Ratio and Opening Limits - Plan