Text on the drawing
HEADER PER PLAN LSTA18 STRAP (ESR-2105) EA. END, HEADER TO KING STUDS, ALL HOLES (2) KING STUDS + TRIMMER (MIN.), MORE PER PLAN (2) 2X TOP PLATE SOLE PLATE / SILL REQUIRED WHERE HEADER UPLIFT EXCEEDS TOENAIL CAPACITY (WIND / SPAN PER PLAN). STRAP MAY BE ON EITHER FACE; DO NOT SPLICE STRAP. CONTINUE UPLIFT PATH TO FOUNDATION (S-FND-164). N.T.S.