Text on the drawing
4X4 POST (OR MULTIPLE STUDS) AT END OF SHEAR WALL SIMPSON HDU5-SDS2.5 HOLDOWN W/ (14) SDS1/4X2-1/2 SCREWS 5/8" DIA. A307 THREADED ROD THRU SILL, SUBFLOOR & BEAM, HOLE 1/16" OVERSIZE 2X SILL PLATE FLOOR JOISTS PER PLAN W/ FACE MOUNT HANGERS 1/4" X 3" X 3" STEEL PLATE WASHER & NUT AT BOTTOM OF BEAM (DO NOT RECESS PLATE INTO BEAM) VERIFY BEAM FOR HOLDOWN UPLIFT / OVERTURNING REACTION W/ ENGINEER. TIGHTEN ANCHOR NUTS JUST PRIOR TO COVERING. I-JOIST AND TRUSS FRAMING SIMILAR. HOLDOWN MODEL PER SHEAR WALL SCHEDULE. GLULAM BEAM PER PLAN N.T.S.