Codes and approvals referenced
Text on the drawing
8" MIN. EMBED 4X6 POST (OR MULTIPLE STUDS) AT END OF SHEAR WALL SIMPSON HDU8-SDS2.5 HOLDOWN W/ (20) SDS1/4X2-1/2 SCREWS 7/8" DIA. F1554 GR. 36 ANCHOR ROD W/ NUT & 1/2"X3"X3" PL. WASHER P.T. 3X SILL PLATE (2) #4 TRUSS BARS EA. WAY, BENT 30 DEG. MAX., HOOKED OVER ANCHOR 12" P.T. / R.C. PODIUM SLAB & REINFORCING PER PLAN 1. HOLES IN HOLDOWN / POST 1/16" OVERSIZE MAX. 2. SPECIAL INSPECTION REQUIRED FOR ANCHOR PLACEMENT. 3. TIGHTEN ANCHOR NUTS JUST PRIOR TO COVERING. 4. COORDINATE ANCHORS W/ P.T. TENDONS BEFORE POUR. N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail