Preview of holdown at foundation - hdu4 detail. The DWG is fully editable.

Codes and approvals referenced

HDU4SB5/8X24

Text on the drawing

EMBED PER MFR. (2) 2X STUDS MIN. PER PLAN SIMPSON HDU4-SDS2.5 HOLDOWN W/ (10) SDS1/4X2-1/2 SCREWS TO POST PRESERVATIVE-TREATED 2X SILL PLATE CONCRETE SLAB PER PLAN #4 CONT. TOP & BOTTOM FOOTING / STEM WALL PER PLAN 5/8" DIA. SB5/8X24 ANCHOR BOLT W/ NUT & WASHER (OR SSTB/PAB EQUIVALENT PER SIMPSON CATALOG) N.T.S.