Codes and approvals referenced
Text on the drawing
MARK HOLDOWN SCREWS TO POST MIN. POST ANCHOR DIA. ANCHOR BOLT HOLDOWN (LB) ALLOW. TENSION (LB) HD3 HDUE3-SDS3 (7) SDS 1/4" x 3" (2) 2X4 OR 4X4 SB5/8X24 3,790 3,790 HD5 HDUE5-SDS3 (10) SDS 1/4" x 3" (2) 2X4 OR 4X4 SB5/8X24 5,375 5,375 HD7 HDUE7-SDS3 (13) SDS 1/4" x 3" (2) 2X4 OR 4X4 SB5/8X24 7,015 6,675 HD9A HDUE9-SDS3.5 (16) SDS 1/4" x 3 1/2" 4X4 SB7/8X24 8,425 8,425 HD9B HDUE9-SDS3.5 (16) SDS 1/4" x 3 1/2" (3) 2X4 OR 4X6 SB7/8X24 9,390 8,795 (9,390*) HD13A HDUE13-SDS3.5 (23) SDS 1/4" x 3 1/2" 4X6 SB1X30 11,900 11,470 (11,900*) HD13B HDUE13-SDS3.5 (23) SDS 1/4" x 3 1/2" 4X8 SB1X30 12,950 11,470 (12,950*) HD17A HDUE17-SDS4.5 (28) SDS 1/4" x 4 1/2" 4X6 SB1X30 16,040 11,470 (14,960*) HD17B HDUE17-SDS4.5 (28) SDS 1/4" x 4 1/2" 6X6 SB1X30 17,685 11,470 (14,960*) ANCHOR BOLTS AT STEM WALL - ALLOWABLE TENSION (LB), SDC C-F STHD STRAP HOLDOWNS - ALLOWABLE TENSION (LB), SDC C-F, CRACKED CONC. ANCHOR DIA. STEM WALL EMBED. MIDWALL CORNER END WALL SLAB EDGE* SSTB16 2,550 2,550 2,550 3,780 SSTB20 3,145 2,960 2,960 4,785 SSTB24 3,740 3,325 3,325 5,790 SSTB28 8,315 7,315 6,395 11,060 SB5/8X24 6,675 5,730 5,730 6,550 SB7/8X24 8,795 7,855 5,730 11,650 SB1X30 11,470 8,315 6,065 14,960 STRAP STEM WALL EMBED. NAILS MIDWALL CORNER END WALL LSTHD8 / 8RJ (16) 2,250 1,950 1,220 STHD10 / 10RJ (18) 2,550 2,550 1,435 STHD14 / 14RJ (22) 3,695 3,695 2,685 LSTHD8 / 8RJ (16) 2,250 1,950 1,610 STHD10 / 10RJ (20) 3,400 2,940 2,175 STHD14 / 14RJ (24) 3,815 3,815 3,500 * SLAB-ON-GRADE EDGE, 12" WIDE FOOTING, MIDWALL. HOLDOWN NOTES 1. ALLOWABLE TENSION = LESSER OF HOLDOWN AND ANCHOR. HOLDOWN LOADS: DF-L / SP POST, CD = 1.6 (ICC-ES ESR-2330). HF / SPF POSTS: REDUCED LOADS PER ESR. 2. ANCHOR LISTED DEVELOPS THE HOLDOWN AT MIDWALL (1.5 x EMBED. FROM END OF WALL), SDC C-F. AT CORNER / END WALL USE ANCHOR TABLE VALUE. (*) = AT SLAB EDGE. 3. ANCHOR LOADS: SIMPSON SSTB / SB (ICC-ES ESR-2611), f'c = 2500 PSI MIN., 1 3/4" MIN. EDGE DISTANCE, (1) #4 CONT. IN TOP 3"-5" OF STEM WALL. 4. POST IS THE MFR. MINIMUM; USE POST PER PLAN IF LARGER. SHEAR WALL EDGE NAILING TO HOLDOWN POST. INSTALL ALL SDS SCREWS; NO LAG SCREW SUBSTITUTION. 5. SET ANCHORS W/ TEMPLATE BEFORE POUR; DO NOT WET-SET. TIGHTEN NUT FINGER TIGHT + 1/3 TURN JUST PRIOR TO COVERING. 6. STHD: EMBEDDED STRAP, 0.148" x 3 1/4" NAILS (ICC-ES ESR-2920). DETACHED 1- AND 2-FAMILY DWELLINGS IN SDC C MAY USE WIND / SDC A-B VALUES. 7. DELETE ROWS NOT USED ON PROJECT. N.T.S.
More general details

Braced Wall Lines and Panels - CRC R602.10 Detail

Wall Sheathing / Shear Wall Schedule

Common Wire Nail Sizes and Nail Loading Detail

Fireblocking and Draftstopping Detail

Mean Roof Height and Stories Above Grade Detail

Vertical Floor Offset - Shear Transfer Detail

Diaphragm Aspect Ratio and Opening Limits - Plan