Preview of holdown with epoxy anchor in existing foundation detail. The DWG is fully editable.

Codes and approvals referenced

ESR-4057HDU11HDU2HDU5HDU8SDSSET-3G

Text on the drawing

EMBED (2) 2X END POST (4X4 MIN.) HOLDOWN PER TABLE, SDS SCREWS TO POST ALL-THREAD ROD W/ NUT & WASHER, TIGHTEN AFTER CURE P.T. SILL PLATE SIMPSON SET-3G EPOXY, FULL DEPTH EXISTING CONC. STEM WALL, 6" MIN. HOLDOWN ROD DIA. EMBED HOLE DIA. HDU2 HDU5 HDU8 HDU11 SIMPSON SET-3G ADHESIVE (ICC-ES ESR-4057); CLEAN HOLE PER MFR., 24 HR CURE BEFORE LOADING. SPECIAL INSPECTION OF ADHESIVE ANCHORS. 1 3/4" MIN. EDGE DISTANCE. FINAL SIZES PER SHEAR WALL SCHEDULE. N.T.S.