Codes and approvals referenced

IUS2.56

Text on the drawing

23/32" T&G WSP SUBFLOOR, GLUED & NAILED 8d @ 6" E.N./12" F.N. 11 7/8" I-JOISTS @ 16" O.C. (OR PER PLAN) WEB STIFFENER EA. SIDE, 1/8" GAP @ TOP, PER MFR. SIMPSON IUS2.56/11.88 HANGER EA. I-JOIST, FILL ALL NAIL HOLES PER MFR. GLULAM BEAM 24F-V4 DF/DF PER PLAN I-JOISTS, HANGERS AND WEB STIFFENERS PER I-JOIST MANUFACTURER INSTALLATION GUIDE. REFER TO DETAIL S-FLR-071 FOR COLLECTOR NAILER AND BLOCKING WHERE REQUIRED. N.T.S.