ICF Stem Wall with Interior Slab on Grade Detail - typical foundations detail drawing, DWG
Preview of icf stem wall with interior slab on grade detail. The DWG is fully editable.

Text on the drawing

ICF STEM WALL: 8" FORM (7 7/8" CORE), 12 1/2" OVERALL #4 VERT. @ 24" O.C., #4 HORIZ. @ 24" O.C. FINISH GRADE, SLOPE AWAY #4 FOOTING DOWELS @ 24" O.C., EMBED 40 BAR DIA. INTO WALL 22"X10" CONT. FOOTING W/ (3) #4 CONT. 4" SLAB ON GRADE W/ #3 @ 18" O.C. EA. WAY AT MID-DEPTH 1/2" ISOLATION JOINT 15 MIL VAPOR RETARDER OVER 4" COMPACTED GRANULAR FILL FOOTING ON UNDISTURBED SOIL OR ENGINEERED FILL, 1500 PSF BEARING, 12" MIN. BELOW GRADE. 2500 PSI CONCRETE, GRADE 60 REBAR. ONE STORY + ROOF LOADS; VERIFY FOOTING WIDTH FOR OTHER CONDITIONS. N.T.S.