Text on the drawing
24 GA. G.I. COPING OVER MEMBRANE, SLOPE TO ROOF 4" FORM PARAPET W/ #4 VERT. @ 16" O.C., #4 HORIZ. TOP ROOFING & BASE FLASHING 8" MIN. UP PARAPET W/ COUNTERFLASHING 1 1/2" TYPE B STEEL ROOF DECK STEEL JOIST, SEAT WELDED TO EMBED PL. (2) 1/8" X 1" FILLET CONT. 3/8" X 6" EMBED PLATE W/ (2) 1/2" X 4" STUDS @ 16" O.C. 8" FORM ICF WALL (7 7/8" CORE), #4 VERT. @ 16" O.C. #4 DOWELS FROM WALL INTO PARAPET, 40 BAR DIA. LAP ANCHOR EA. JOIST BRIDGING ROW TO WALL W/ L2X2X1/4 CLIP AND 3/8" EXPANSION ANCHOR. JOIST SEAT 4" MIN. BEARING ON EMBED PLATE (SJI). 1/2" GYPSUM BOARD OVER INTERIOR FOAM. N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail