Text on the drawing

7 7/8" CORE VERT. BAR AT CENTER OF CORE (1 3/16" OFF CENTER AT RETAINING) HORIZ. BAR IN WEB CLIP NOTCH, 2 3/8" FROM FORM FACE 2 5/16" EPS EA. SIDE A - SECTION PLASTIC WEBS @ 8" O.C. VERT. BARS BETWEEN WEBS @ 16" O.C. B - PLAN TYPICAL ABOVE-GRADE WALL: #4 VERT. @ 16" O.C., #4 HORIZ. @ 16" O.C. IN WEB CLIPS. LAP 40 BAR DIA. BASEMENT / RETAINING WALLS: VERT. BARS TOWARD INTERIOR FACE PER ICF MFR. TABLE OR ENGINEERED DESIGN. N.T.S.