Text on the drawing
A - SQUARE OPENING P.T. 2X12 ROUGH BUCK W/ SILL GASKET 1/4" CONC. SCREWS @ 16" O.C. STAGGERED, 1 1/2" MIN. EMBED #5 VERT. EA. SIDE OF OPENING, FULL HEIGHT B - FLARED OPENING P.T. 2X6 + 2X10 FLARED BUCK W/ SILL GASKET WINDOW PER MFR. EIFS LAMINA RETURNED TO FRAME, SEALANT 1 1/2" MIN. CONCRETE COVER TO BUCK FASTENERS. HEADER BARS (2) #5 X OPENING + 4'-0" OVER OPENINGS TO 6'-0". FLASH SILL WITH SLOPED SELF-ADHERED PAN UNDER BUCK. 1/2" GYPSUM BOARD RETURNED TO BUCK ON INTERIOR. N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail