Codes and approvals referenced
Text on the drawing
18" MIN. 12" MIN. 18" SQ. 23/32" T&G WSP SUBFLOOR W/ 8d @ 6" E.N./12" F.N. 2X10 JOISTS @ 16" O.C. W/ (3) 8d TOENAILS TO BEAM 2X SOLID BLOCKING W/ (3) 10d EA. END (3) 2X8 BUILT-UP BEAM W/ (2) ROWS 16d @ 12" SIMPSON BC4 POST CAP W/ (12) 16d 4X4 P.T. POST SIMPSON ABU44Z W/ 5/8" A.B., 7" MIN. EMBED 18" SQ. X 12" CONC. PAD (OR PRECAST PIER), TOP 2" ABOVE GRADE CRAWLSPACE GRADE PER CRC R408 / R304. WOOD WITHIN 18" OF GRADE (JOISTS) OR 12" (BEAMS) SHALL BE P.T. PROVIDE TERMITE SHIELD AS REQ'D. 1500 PSF ALLOWABLE SOIL BEARING. N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail