TYPDETAIL

Home / Foundations

Interior Pier - Post and Girder at Crawl Space Detail - typical foundations detail drawing, DWG
Preview of interior pier - post and girder at crawl space detail. The DWG is fully editable.

Codes and approvals referenced

PB44

Text on the drawing

18" SQ. 6" MIN. 4X10 GIRDER, SPLICE OVER POST SIMPSON AC4Z POST CAP EA. SIDE 4X4 P.T. POST (4X6 AT SPLICE) SIMPSON PB44 POST BASE, CAST IN PIER 14"X14" PIER, TOP 6" MIN. ABOVE GRADE 18"X18"X8" FOOTING W/ (3) #4 EA. WAY FLOOR LOADS ONLY (NO BEARING PARTITIONS): 36 SQ. FT. OF FLOOR MAX. PER PIER AT 1500 PSF SOIL BEARING. BEAR ON NATURAL GRADE OR FILL COMPACTED TO 90%. 18" CLEAR GRADE TO JOISTS, 12" TO GIRDER. N.T.S.