Codes and approvals referenced
Text on the drawing
23/32" T&G WSP SUBFLOOR, PANEL JOINT OVER BLOCKING 8d @ 6" O.C. E.N. EA. SIDE OF PANEL JOINT INTO BLOCKING 2X SOLID BLOCKING (FULL DEPTH) W/ (3) 10d TOENAILS EA. END 2X10 DF-L NO. 2 JOISTS @ 16" O.C., 1 1/2" MIN. BEARING SIMPSON A35 CLIP @ 24" O.C. W/ (12) 8dX1-1/2 (AT COLLECTOR) TOENAIL EA. JOIST TO BEAM W/ (3) 8d GLULAM BEAM 24F-V4 DF/DF PER PLAN BLOCKING AND SHEAR CLIPS REQUIRED WHERE BEAM LINE IS A DIAPHRAGM BOUNDARY / COLLECTOR. B.N. / E.N. PER DIAPHRAGM SCHEDULE WHERE GREATER. N.T.S.