AWC NDS 12NDS 12.1.4.3

Text on the drawing

STD. CUT WASHER UNDER HEAD SHANK LEAD HOLE = SHANK DIA., DEPTH = UNTHREADED SHANK LENGTH THREAD LEAD HOLE: 40%-70% OF SHANK DIA. (G ≤ 0.50, E.G. DF-L, HF) SPECIFIC GRAVITY (G) THREAD LEAD HOLE G > 0.6 65% - 85% D 0.5 < G ≤ 0.6 60% - 75% D G ≤ 0.5 40% - 70% D PER AWC NDS 12.1.4. INSERT BY TURNING W/ WRENCH, NOT DRIVING; SOAP OR LUBRICANT PERMITTED. LAGS 3/8" DIA. AND SMALLER IN G ≤ 0.5 MAY BE INSTALLED W/O LEAD HOLE IF NO SPLITTING (NDS 12.1.4.3). MAIN MEMBER 3" = 1'-0"