TYPDETAIL

Home / Masonry

Masonry Expansion Joint - Fire Rated Detail - typical masonry detail drawing, DWG
Preview of masonry expansion joint - fire rated detail. The DWG is fully editable.

Codes and approvals referenced

ASTM E1966

Text on the drawing

8" CMU WALL EA. SIDE SEALANT, 7/8" MIN. DEPTH, & BACKER ROD EA. FACE 4"X1/4" STEEL PLATE CLOSURE, 1/4" EXP. ANCHORS @ 24" O.C. ONE SIDE FURRED WALLS: DO NOT FASTEN ACROSS JOINT JOINT ASSEMBLY LISTED FOR THE WALL RATING (ASTM E1966). JOINT WIDTH 1" TYPICAL. NO REINFORCING ACROSS EXPANSION JOINT. ALIGN WITH STRUCTURAL SEPARATION IN ROOF AND FOUNDATION. CERAMIC FIBER BLANKET: 1 1/2" (1-HR), 3" (2-HR), 4 1/2" (4-HR) COMPRESSED N.T.S.