Codes and approvals referenced
Text on the drawing
8" CMU WALL EA. SIDE SEALANT, 7/8" MIN. DEPTH, & BACKER ROD EA. FACE 4"X1/4" STEEL PLATE CLOSURE, 1/4" EXP. ANCHORS @ 24" O.C. ONE SIDE FURRED WALLS: DO NOT FASTEN ACROSS JOINT JOINT ASSEMBLY LISTED FOR THE WALL RATING (ASTM E1966). JOINT WIDTH 1" TYPICAL. NO REINFORCING ACROSS EXPANSION JOINT. ALIGN WITH STRUCTURAL SEPARATION IN ROOF AND FOUNDATION. CERAMIC FIBER BLANKET: 1 1/2" (1-HR), 3" (2-HR), 4 1/2" (4-HR) COMPRESSED N.T.S.
More masonry details

CMU Garden / Fence Wall - 4'-0" High Detail

CMU Garden / Fence Wall - 6'-0" High Detail

CMU Garden / Fence Wall - 8'-0" High Detail

CMU Stem Wall on Continuous Footing Detail

Wood Truss Bearing at CMU Opening - Angle Lintel Detail

Roof Ledger at CMU Wall - Joists in Hangers Detail

CMU Control Joint - Plan