Preview of roof ledger at cmu wall - joists in hangers detail. The DWG is fully editable.

Codes and approvals referenced

ASCE 7 12LUS28

Text on the drawing

G.I. CAP, SLOPE TO ROOF REGLET & COUNTERFLASHING, SAWCUT 1 1/2" X 3/8" 40 MIL ELASTOMERIC BASE FLASHING OVER CANT, 8" MIN. UP WALL 2X8 ROOF JOISTS @ 16" O.C. IN SIMPSON LUS28 HANGERS BOND BEAM W/ (2) #5 8" CMU WALL, #5 VERT. @ 32" O.C., CONT. TO PARAPET SIMPSON PA51 STRAP @ 48" O.C., ROOF DIAPHRAGM TO WALL OUT-OF-PLANE WALL ANCHORAGE PER ASCE 7 12.11; NO CROSS-GRAIN BENDING OF LEDGER. B.N. ROOF SHEATHING 10d @ 4" O.C. TO LEDGER. 1500 PSI MASONRY f'm, TYPE S MORTAR, 2000 PSI GROUT. P.T. 4X8 LEDGER W/ 3/4" A.B. @ 32" O.C., 5" EMBED IN BOND BEAM N.T.S.