Text on the drawing
EXPOSURE MEMBER BARS COVER CAST AGAINST AND PERMANENTLY IN CONTACT W/ GROUND ALL ALL EXPOSED TO WEATHER OR IN CONTACT W/ GROUND ALL #6 - #18 EXPOSED TO WEATHER OR IN CONTACT W/ GROUND ALL #5 & SMALLER NOT EXPOSED TO WEATHER OR GROUND SLABS, JOISTS, WALLS #14, #18 NOT EXPOSED TO WEATHER OR GROUND SLABS, JOISTS, WALLS #11 & SMALLER NOT EXPOSED TO WEATHER OR GROUND BEAMS, COLUMNS ALL (INCL. TIES) FORMED, EXPOSED TO EARTH OR WEATHER: 2" (#6+), 1 1/2" (#5-) CAST AGAINST EARTH: 3" PER ACI 318-19 TABLE 20.5.1.3.1 (CBC 1901.2). COVER MEASURED TO OUTERMOST BAR, TIE OR STIRRUP. PROVIDE CHAIRS / DOBIES TO HOLD COVER; CMU GROUT COVER PER TMS 402. N.T.S.