TYPDETAIL

Home / Walls & Shear Walls

New Post in Existing Wall to New Footing - Section - typical walls & shear walls detail drawing, DWG
Preview of new post in existing wall to new footing - section. The DWG is fully editable.

Codes and approvals referenced

ESR-1622

Text on the drawing

NEW 6X POST IN (E) WALL (OR BUILT-UP STUDS PER PLAN), BEAM ABOVE SOLID BLOCKING AT FLOOR UNDER POST, FULL BEARING POST IN CRAWL SPACE TO FOOTING ABU POST BASE (ESR-1622) W/ A.B. PER MFR. NEW PAD FOOTING PER PLAN CONTINUOUS LOAD PATH FROM BEAM TO FOUNDATION. ON SLAB-ON-GRADE: SAW-CUT AND POUR PAD FOOTING UNDER POST (S-FND-163). FOOTING SIZE PER PLAN / SOILS REPORT. N.T.S.