Text on the drawing
6X6 P.T. POST ABU66Z POST BASE (ESR-1622) W/ 5/8" A.B., 7" EMBED #4 DOWELS @ 12" O.C., 4" INTO (E) SLAB W/ EPOXY (ESR-4057) NEW 24"X24"X18" PAD FOOTING W/ (3) #4 E.W. BOT., 3" CLR. (E) SLAB SAW-CUT (E) SLAB 2" MIN. BEYOND PAD; ROUGHEN EDGES. PAD SIZE PER PLAN (MATCH UPLIFT). POST BASE MAY BE PLACED ON SLAB ONLY WHERE ENGINEER CONFIRMS SLAB ADEQUATE. N.T.S.