TYPDETAIL

Home / Foundations

Patio Cover Post at Existing Slab - New Pad Footing Detail - typical foundations detail drawing, DWG
Preview of patio cover post at existing slab - new pad footing detail. The DWG is fully editable.

Codes and approvals referenced

ESR-1622ESR-4057

Text on the drawing

6X6 P.T. POST ABU66Z POST BASE (ESR-1622) W/ 5/8" A.B., 7" EMBED #4 DOWELS @ 12" O.C., 4" INTO (E) SLAB W/ EPOXY (ESR-4057) NEW 24"X24"X18" PAD FOOTING W/ (3) #4 E.W. BOT., 3" CLR. (E) SLAB SAW-CUT (E) SLAB 2" MIN. BEYOND PAD; ROUGHEN EDGES. PAD SIZE PER PLAN (MATCH UPLIFT). POST BASE MAY BE PLACED ON SLAB ONLY WHERE ENGINEER CONFIRMS SLAB ADEQUATE. N.T.S.