Text on the drawing
12" TYP. 24" MIN. 2X6 STUD WALL W/ 15/32" WSP & E.N. PER S.W. SCHED. PLUMBING CHASE PER ARCH. P.T. 2X6 SILL W/ 5/8" A.B. @ 48" O.C. W/ 3"X3"X0.229" PLATE WASHERS HOLDOWN ANCHOR W/ HVY. HEX NUT (WHERE OCCURS) #4 DOWELS @ 18" O.C., 18" MIN. LAP INTO SLAB (3) #5 BOT. CONT., 3" CLR. 5" SLAB W/ #4 @ 18" O.C. E.W. THICKENED SLAB, 15" DEEP, 1:1 SIDES SLEEVE ALL PLUMBING THROUGH THICKENED SLAB; DO NOT CUT REINFORCING. COORDINATE CHASE WIDTH W/ ARCH. AND PLUMBING. HOLDOWNS PER SHEAR WALL PLAN. N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail