Text on the drawing
POST / KING STUDS ABOVE PER PLAN SQUASH BLOCK: SOLID 4X OR (2) 2X, 1/16" TALLER THAN JOIST, FULL WIDTH OF POST ABOVE FLOOR JOIST PER PLAN POST BELOW, ALIGN W/ POST ABOVE (2) 2X TOP PLATE PROVIDE CONTINUOUS LOAD PATH AT ALL POSTS AND BEAM BEARINGS TO FOUNDATION. SQUASH BLOCKS AT I-JOISTS PER MANUFACTURER; DO NOT RELY ON RIM / FLANGES FOR POINT LOADS. N.T.S.