Text on the drawing
WALL / SILL PER PLAN, SILL 2" MIN. ABOVE PORCH SLAB, FLASHED 4" PORCH SLAB W/ #3 @ 18" O.C. E.W., SLOPE 1/4" PER FT. AWAY FROM HOUSE #4 DOWEL @ 24" O.C., 6" EMBED W/ EPOXY (SET-3G, ESR-4057), 24" INTO SLAB 4" COMPACTED BASE (E) / NEW STEM WALL PER PLAN ROUGHEN STEM WALL FACE AT SLAB. DRILL AND CLEAN HOLES PER ADHESIVE ESR. CONTROL JOINTS PER S-SLB SERIES; NO WOOD WITHIN 2" OF PORCH SLAB U.N.O. N.T.S.