Preview of post base - 4x6 post detail. The DWG is fully editable.

Codes and approvals referenced

CRC R304.1.4).

Text on the drawing

8" MIN. 4X6 POST PER PLAN SIMPSON ABU46Z POST BASE W/ (12) 16d TO POST 5/8" DIA. A.B. (OR SIMPSON SSTB / J-BOLT) W/ NUT & WASHER 1" STANDOFF 28" MIN. (OR PER PLAN) POST BASE PROVIDES 1" STANDOFF ABOVE CONCRETE (CRC R304.1.4). INSTALL PER SIMPSON STRONG-TIE CATALOG. NOT FOR UNBRACED / CANTILEVERED POSTS (FENCES, UNBRACED CARPORTS). CONCRETE SLAB / FOOTING PER PLAN (3) #4 EA. WAY, 3" CLR. N.T.S.