
Codes and approvals referenced
Text on the drawing
SECTION PLAN (2) #4 x 18" REBAR DOWELS, DRIVEN THRU PRECAST HOLES PRECAST CONC. WHEEL STOP, YELLOW / BLUE AT ACC. STALLS SET 2'-6" FROM FRONT OF STALL (VERIFY W/ SITE PLAN) AND CENTERED IN STALL. NOT PERMITTED WITHIN ACCESSIBLE ROUTE / ACCESS AISLE (CBC 11B-502.7). EPOXY TO CONCRETE PAVEMENT IN LIEU OF DOWELS. DETAIL # - PRECAST CONCRETE WHEEL STOP NOT TO SCALE







