Codes and approvals referenced
Text on the drawing
3'-0" MAX. EXPOSED CAP UNIT ADHERED W/ CONCRETE ADHESIVE PER MFR. 12" MIN. 3/4" DRAIN AGGREGATE BEHIND AND IN UNIT CORES FILTER FABRIC (MIRAFI 140N OR EQUAL) BETWEEN DRAIN ROCK AND BACKFILL 4" PERF. PVC DRAIN, HOLES DOWN, TO DAYLIGHT @ 50'-0" O.C. MAX. 6" COMPACTED CRUSHED ROCK LEVELING PAD, 24" WIDE SRW UNITS, SETBACK PER MFR. 1ST COURSE BURIED 6" MIN. GRAVITY WALL W/ LEVEL BACKSLOPE AND NO SURCHARGE ONLY. TALLER WALLS, SLOPES OR SURCHARGE: GEOGRID PER ENGINEERED DESIGN. INSTALL PER MFR.; WALLS OVER 4'-0" OR SURCHARGED REQUIRE PERMIT (CBC 105.2). 3/4" = 1'-0"