TYPDETAIL

Home / Civil

Sewer Cleanout to Grade - Paved Area Detail - typical civil detail drawing, DWG
Preview of sewer cleanout to grade - paved area detail. The DWG is fully editable.

Codes and approvals referenced

CPC 707.

Text on the drawing

TRAFFIC-RATED CAST IRON LID MARKED "SEWER" 10" PRECAST CONC. BOX (H-20) THREADED BRASS PLUG SAME SIZE AS MAIN, 4" MIN., ABS/PVC SCH. 40 RISER WYE FITTING BUILDING SEWER PER PLAN 12" WIDE X 8" THICK CONC. COLLAR PER CPC 707. CLEANOUT AT PROPERTY LINE / 2'-0" OUTSIDE BUILDING AND @ 100'-0" O.C. MAX. LID FLUSH W/ FINISH GRADE (1" ABOVE IN LANDSCAPE). DETAIL # - SEWER CLEANOUT TO GRADE - PAVED AREA NOT TO SCALE

More civil details

Fiber Roll Detail - DWG drawing

Fiber Roll Detail

Concrete Washout Detail - DWG drawing

Concrete Washout Detail

Construction Entrance/Exit Detail - DWG drawing

Construction Entrance/Exit Detail

Storm Drain Inlet Protection Detail - DWG drawing

Storm Drain Inlet Protection Detail

Water and Sewer Separation Detail - DWG drawing

Water and Sewer Separation Detail

Sewer Cleanout Detail - DWG drawing

Sewer Cleanout Detail

Wet Tap Connection Detail - DWG drawing

Wet Tap Connection Detail