Text on the drawing
TRAFFIC-RATED CAST IRON LID MARKED "SEWER" 10" PRECAST CONC. BOX (H-20) THREADED BRASS PLUG SAME SIZE AS MAIN, 4" MIN., ABS/PVC SCH. 40 RISER WYE FITTING BUILDING SEWER PER PLAN 12" WIDE X 8" THICK CONC. COLLAR PER CPC 707. CLEANOUT AT PROPERTY LINE / 2'-0" OUTSIDE BUILDING AND @ 100'-0" O.C. MAX. LID FLUSH W/ FINISH GRADE (1" ABOVE IN LANDSCAPE). DETAIL # - SEWER CLEANOUT TO GRADE - PAVED AREA NOT TO SCALE