Text on the drawing
FLOOR DECKING: 2X6 T&G W/ UNDERLAYMENT TIMBER FRAME BEAM SIP SCREWS @ 24" O.C., 1 1/2" MIN. INTO TIMBER 6 1/2" SIP WALL, CONT. PAST FLOOR EXT. FINISH & WRB SIP SCREW SIZE AND SPACING PER PANEL MFR. ICC-ES REPORT AND PLAN. SEAL PANEL TO TIMBER W/ SIP TAPE AT INSIDE FACE FOR AIR BARRIER CONTINUITY. N.T.S.